Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 2 de 2
Filter
Add filters








Language
Year range
1.
Chinese Journal of Radiological Medicine and Protection ; (12): 679-684, 2020.
Article in Chinese | WPRIM | ID: wpr-868500

ABSTRACT

Objective:To develop a deep learning model for predicting three-dimensional (3D) voxel-wise dose distributions for intensity-modulated radiotherapy (IMRT).Methods:A total of 110 postoperative rectal cancer cases treated by IMRT were considered in the study, of which 90 cases were randomly selected as the training-validating set and the remaining as the testing set. A 3D deep learning model named 3D U-Res-Net was constructed to predict 3D dose distributions. Three types of 3D matrices from CT images, structure sets and beam configurations were fed into the independent input channel, respectively, and the 3D matrix of IMRT dose distributions was taken as the output to train the 3D model. The obtained 3D model was used to predict new 3D dose distributions. The predicted accuracy was evaluated in two aspects: the average dose prediction bias and mean absolute errors (MAEs)of all voxels within the body, the dice similarity coefficients (DSCs), Hausdorff distance(HD 95) and mean surface distance (MSD) of different isodose surfaces were used to address the spatial correspondence between predicted and clinical delivered 3D dose distributions; the dosimetric index (DI) including homogeneity index, conformity index, V50, V45 for PTV and OARs between predicted and clinical truth were statistically analyzed with the paired-samples t test. Results:For the 20 testing cases, the average prediction bias ranged from -2.12% to 2.88%, and the MAEs varied from 2.55% to 5.75%. The DSCs value was above 0.9 for all isodose surfaces, the average MSD ranged from 0.21 cm to 0.45 cm, and the average HD 95 varied from 0.61 cm to 1.54 cm. There was no statistically significant difference for all DIs, except for bladder Dmean. Conclusions:This study developed a deep learning model based on 3D U-Res-Net by considering beam configurations input and achieved an accurate 3D voxel-wise dose prediction for rectal cancer treated by IMRT.

2.
Chinese Journal of Radiation Oncology ; (6): 536-542, 2019.
Article in Chinese | WPRIM | ID: wpr-755067

ABSTRACT

Objective To evaluate the feasibility of utilizing dose-volume histogram (DVH) prediction models of organs at risk (OARs) to deliver automatic treatment planning of prostate cancer.Methods The training set included 30 cases randomly selected from a database of 42 cases of prostate cancer receiving treatment planning.The bladder and rectum were divided into sub-volumes (Ai) of 3 mm in layer thickness according to the spatial distance from the boundary of planning target volume (PTV).A skewed normal Gaussian function was adopted to fit the differential DVH of Ai,and a precise mathematical model was built after optimization.Using the embedded C++ subroutine of Pinnacle scripa,ahe volume of each Ai of the remaining validation set for 12 patients was obtained to predict the DVH parameters of these OARa,ahich were used as the objective functions to create personalized Pinnacle script.Finalla,automatic plans were generated using the script.The dosimetric differences among the original clinical plannina,aredicted value and the automatic treatment planning were statistically compared with paired t-test.Results DVH residual analysis demonstrated that predictive volume fraction of the bladder and rectum above 6 000 cGy were lower than those of the original clinical planning.The automatic treatment planning significantly reduced the V70,V60,V50 of the bladder and the V70 and V60 of the rectum than the original clinical planning (all P<0.05),the coverage and conformal index (CI) of PTV remained unchangea,and the homogeneity index (HI) was slightly decreased with no statistical significance (P> 0.05).Conclusion The automatic treatment planning of the prostate cancer based on the DVH prediction models can reduce the irradiation dose of OARs and improve the treatment planning efficiency.

SELECTION OF CITATIONS
SEARCH DETAIL